The D3D D9 security system comes with a range of sensor equipments like the PIR motion sensor, the door/window sensor, the smoke detector sensor, the gas leakage sensor etc. which work in co-ordination with the central unit and notify the users in case of any unwanted action taking place.
The door/window sensors of the D3D D9 security system work wirelessly over the RF transmission. Let us quickly understand how to configure the D3D door/window sensor through the main control unit of the system.
The D3D door/window sensor consist of two parts. One is the electronic part that consists of the circuit and the cell mounting. And the other is the magnetic part.
The electronic part consist of two LEDs – Red and Green, and a Test Push Button.
Step 1: First of all make sure that you have inserted the cells in the door/window sensor properly through the back lid. On inserting it properly, press the PUSH TO TEST button and the Red Alarm LED on the sensor will glow, giving you a confirmation that the sensor is working fine.
Step 2: Turn on the main control unit. In the Menu section go to Setup–>Edit Zones–>Edit RF Detector. In the Edit RF section, you can configure various kind of security sensor that come along with the D3D system. The first option of Delete All is common in case you want to delete all the configured sensors in your system.
The D3D D9 security system allows you to configure 99 various type of sensors.
Step 3: Go to the Empty option and press Enter key. Here, you will provided with two options of Add and Delete. Click on Add.
Since you have entered the Empty option, it means that there is no device configured on that option at that moment. In case, for any option the device is configured, you will see the Used status in place of Empty.
Step 4: Once you click on Add option, the display on the main control unit will ask you to Turn On Device. Here “Device” means your sensor unit you want to configure. This can be a remote, smoke sensor, motion sensor, door/windows sensor etc.
Here by Turn on Device, it means trigger the sensor action action. Once this message appears, trigger the sensor action by pressing the TEST TO PUSH button present on the electronic part of the sensor. The Red “Alarm” LED will blink and a RF Code will be transmitted to the main control unit.
Once the code appears on the display screen of the main control unit, press Enter key. Repeat the same action for second time confirmation and press Enter key again.
You can also trigger the D3D door/window sensor by split action as shown in the figure below.
Step 5: Here you will be asked to select the Zone Type for the sensor as per your utility. [Read: Zone Type explanations for the D3D security system]
Step 6: After selection of your Zone Type, you will get an Operation OK message on the unit. Now the Empty status of the Zone location where you have configured this sensor will turn to be showing as Used.
Just like the door/window sensor, you can similarly configure the PIR motion sensor, the smoke detector sensor and others.